Makes we repair
Common fault codes, explained in full
Sixteen common codes are explained in full, and so are Worcester Bosch's codes. Each says what the code means on every make that shows it, what you can safely check, and when to ring.
- F28Vaillant and Glow-worm: the boiler tried to light and found no flame.
- F22Vaillant and Glow-worm: the water pressure is too low.
- F75Vaillant and Glow-worm: the pressure didn't rise when the pump started.
- L2Ideal: the boiler tried to light five times, then locked out.
- F1Ideal: the water pressure is too low. An older Glow-worm means something else.
- F2Ideal: the flame went out. Viessmann: the overheat cut-out has tripped.
- E119Baxi and Potterton: the water pressure has dropped below 0.5 bar.
- E133Baxi and Potterton: the gas supply was cut, or the flame didn't light.
- F29Vaillant and Glow-worm: the flame went out and the boiler couldn't relight.
- F83Vaillant and Glow-worm: the boiler lit, but the water barely warmed.
- F62Vaillant and Glow-worm: the flame went out late as the gas valve shut.
- F54Vaillant: too little gas reached the boiler as it started.
- E125Baxi and Potterton: the water isn't circulating properly.
- F3Ideal: a fan fault. Viessmann: a flame seen before the burner lit.
- A21Worcester Bosch: a code from the heating controls, often a lost signal.
- Alpha E01Alpha: the boiler tried to light and found no flame.
- Worcester Bosch codesThe Greenstar's codes and lights, and what each one means.
Codes by make
Every make we repair has its codes set out in full, the main ones explained and a list of the rest. Pick your boiler's maker.
Not sure of your boiler's make? How to find it.
Is your boiler from a make no longer sold? We explain the codes, lights and faults of Halstead, Johnson & Starley, Malvern and Myson boilers.
Every other code, make by make
Each make's main codes are listed below, every one linked to where it is explained. Each make ends with a link to its full list for the rest. Open your boiler's make.

Vaillant: F. and two or three figures
Vaillant boilers show F. and two figures, such as F.28. The current ecoTEC plus, from 2023, shows three, such as F.028, with the same meaning. Some codes on an older ecoTEC, turboMAX or ecoMAX mean something else. Which Vaillant boiler shows which kind of code.
- F.23 (F.023): the water isn't moving round fast enough
- F.20 (F.020): the overheat cut-out has stopped the burner
- F.24 (F.024): the temperature rose too fast
- F.27 (F.027): a flame where there shouldn't be one
- F.76 (F.076): the main heat exchanger's overheat protection
- F.28: the boiler tried to light and found no flame
- F.29 (F.029): the flame went out and wouldn't relight
- F.22: the water pressure is too low
- F.75: the pressure doesn't rise when the pump starts
- F.54: not enough gas pressure at start-up
- F.62 (F.062): the flame went out late after the gas valve shut
- F.83 (F.083): the burner lit, but the water barely warmed
The rest of the Vaillant codes are in one list on the Vaillant page.
Worcester Bosch: numbers, letters or a blue light
Worcester Bosch Greenstar boilers show a fault in one of five ways, by age. Some show a number with a line of text, or a number with an H. Some show two characters with a three-figure number, such as EA 227, and some two characters alone. Others flash a blue light in a pattern. Which Worcester Bosch boiler shows which kind of code.
- EA 227 (Greenstar i System, Si and CDi Compact) or 227 (8000+, 8000 Life, 4000, 2000, 1000): no flame
- EA 229 (Greenstar i System, Si and CDi Compact) or 229 (8000+, 8000 Life, 2000, 1000): the flame went out while the boiler was running
- E9 224 (Greenstar i System, Si and CDi Compact) or 224 (8000+, 8000 Life, 4000, 2000, 1000): an overheat safety device has tripped
- 1017 (Greenstar 8000+, 8000 Life, 4000): the system pressure is low
- 2971 (Greenstar 8000+, 8000 Life, 4000, 2000): the pressure is too low and the boiler has stopped
- A1 281 (Greenstar i System, Si and CDi Compact) or 281 (8000+, 8000 Life, 4000, 2000): the pump
- D5 (Highflow, FS CDi Regular, 2012 Greenstar 24/28): a different fault on each range
- C6 (Greenstar i System, Si and CDi Compact, CDi Classic, Highflow, FS CDi, 2012 24/28): the fan
- 2980 (Greenstar 8000+, 4000, 1000): a super lock-out
- A21: a code from the Greenstar heating controls, often a lost signal
Baxi: E and a number, or numbers with dots
Baxi's current Combi 2 and System 2 show a letter and numbers with dots, such as A.02.06. Older Baxi boilers show E and a number, such as E133, and the Heat boilers a light. The same number can mean something else on another range. Which Baxi boiler shows which kind of code.
- E110: the boiler has overheated
- E160: a fan fault
- A.02.06: a low-pressure warning, and the boiler keeps running
- H.02.07: the water pressure is too low, and the boiler has stopped
- E118: the water pressure is too low, under 0.5 bar
- E.04.10: the burner didn't light after 4 tries
- E.01.17: no water moving, and the boiler has locked out
- H.01.18: no water moving, and the boiler waits
- E119: the water pressure has dropped below 0.5 bar
- E125: the heating water isn't moving round properly
- E133: the gas supply was interrupted, or the flame didn't light
The rest of the Baxi codes are in one list on the Baxi page.
An older Baxi Duo-tec's codes, edition by edition.
Ideal: a letter and a number, or words
Ideal's Logic+, Logic Max and Vogue name the fault in words. The Logic Combi2 and i-mini show a letter and two figures, such as L 02. The ESP1, the Exclusive2 and older Logic boilers show a letter and one figure, such as L2, with the same meaning. Which Ideal boiler shows which kind of code.
- L1 (Overheat): too hot, or no water moving
- LC (Too Many Restarts): five restarts in 15 minutes
- L6 (Flame On Before Gas On): a flame before the gas opens
- L8 (and L 08): the Restart button, the main board or the fan, by range
- F4 and F5 (also L4 and L5): the flow and return sensors
- F7 (Low Mains Voltage): too little electricity
- L2 (Ignition Lockout): the boiler tried to light five times and failed
- F1 (Low Water Pressure): the pressure is too low for the boiler to run
- F2 (Flame Loss): the flame went out while the boiler was running
- F3 (Fan Fault): the fan isn't running as the main board expects
The rest of the Ideal codes are in one list on the Ideal page.
Viessmann: two characters, or a number
Viessmann's Vitodens boilers before the One Base show two characters beside a fault symbol, such as F4. The current One Base boilers show a number, and the same characters mean other things there. Which Viessmann boiler shows which kind of code.
- F4: no flame signal
- EE: no flame as the burner starts, on a 200-W B2HB
- F8: the gas valve closes too late, or won't close on a 200-W B2HB
- F9: the fan is too slow at start-up
- FA: the fan doesn't come to rest, or on a 200-W B2HB doesn't reach its speed
- FC, Fd and FF: the control unit, or on a 200-W B2HB the gas valve or the flue (FC)
- F2: the overheat cut-out has tripped
- F3: a flame signal before the burner lights
The rest of the Viessmann codes are in one list on the Viessmann page.
Glow-worm: F. and two figures
Glow-worm's current boilers show F. and two figures, such as F.28, and the Betacom2 and Ultracom2 drop the dot. The Flexicom, the first Ultracom and older boilers flash F and a number that means something else. On those, F1 is an ignition fault. Which Glow-worm boiler shows which kind of code.
- F.20: the overheat cut-out has shut the boiler off
- F.23: the flow and return are too far apart
- F.24: the temperature rises too fast
- F.27: a flame signal with the burner off
- F.32: fan fault
- F.28: the boiler tried to light and failed
- F.29: the flame went out and wouldn't relight
- F.22: there isn't enough water in the boiler
- F.75: a pressure or pump fault found as the pump starts
- F.62: the flame went out late after the gas valve shut
- F.83: the burner lit, but the water barely warmed
- F1 on an older Flexicom, Ultracom or cxi: an ignition fault
- F3 on an older cxi, Flexicom or Ultracom: the fan couldn't reach its lighting speed
The rest of the Glow-worm codes are in one list on the Glow-worm page.
Potterton: E and a number, or a light
Potterton boilers with a display show E and a number, such as E133, which a two-figure display splits into E1 and 33. The Titanium Heat uses a coloured light, and the Performa and Suprima use lights. Low pressure is E119 on the Promax, Titanium and Gold, and E118 on the Assure and Ultra. Which Potterton boiler shows which kind of code.
- A Potterton boiler flashing a green light: which boiler is it?
- E118: the water pressure is too low, on the Assure and the Promax Ultra
- E110: the safety thermostat has tripped
- E130: the flue has overheated
- E160: a fan fault
- E28: the flue sensor, or a blocked flue or condensate pipe
- E20 and E50: the heating and hot water sensors
- E119: the water pressure has dropped below 0.5 bar
- E125: the heating water isn't moving round as it should
- E133: the gas supply was interrupted, or the flame didn't light
The rest of the Potterton codes are in one list on the Potterton page.
A Potterton Suprima's lights and faults.
Alpha: E and a number, or lights
Alpha boilers give each fault a number, written E01, E10 and so on, on a screen. The older CD combis show a pattern of four lights. Which Alpha boiler shows which kind of code.
- E10: the system pressure is too low
- E02: the overheat sensor has tripped
- E03: the flue gas is too hot
- E16: a fan fault
- E38 and E43: the flame lit, then went out
- E01: the boiler tried to light and found no flame
The rest of the Alpha codes are in one list on the Alpha page.
Vokera: an A, E or AL code, or lights
Vokera's codes have changed over the years. The older Compact A, Vision, Unica i and Mynute i show A01 to A11. The Vibe MAX and Easi-Heat i show A10 and up. The Synergy, Pinnacle and Evolve show E codes, and older boilers show AL codes or lights. Which Vokera boiler shows which kind of code.
- A01: the boiler didn't light
- A02: the limit thermostat has tripped
- A03: no signal from the fan
- A04: the system pressure is too low
- A06 to A09: a sensor fault
- A11: a flame where there shouldn't be one
The rest of the Vokera codes are in one list on the Vokera page.
Ariston: three figures, sometimes in words
Ariston's E-Combi ONE and Clas ONE flash three figures, and Err with the code when they lock out. The Genus ONE+ and Alteas ONE+ print the code with its meaning in words. The first figure says where the fault is. Which Ariston boiler shows which kind of code.
- 108: the pressure is low, and the system needs filling
- 501: no flame, and the boiler has locked out
- 101: the heating water has overheated
- 109: the pressure is too high
- 304: the reset key was pressed too many times
- 502: a flame sensed with the gas valve closed
The rest of the Ariston codes are in one list on the Ariston page.
Keston: words, a code or a light
Keston's Combi 2 and System 2 name the fault in words, as Ideal's Logic+ Combi2 does. The System S30 shows a letter and a number, such as L2, and the Heat 2 shows Fault and a number. Which Keston boiler shows which kind of code.
- Ignition Lockout (L2 on a System S30)
- Flame Loss (F2 on a System S30)
- Low Water Pressure (F1 on a System S30)
- Overheat (L1 on a System S30)
- No Water Flow (Combi 2 and System 2)
- Too Many Restarts (LC on a System S30)
- L2: the boiler tried to light and locked out
- F1: the water pressure is too low for the boiler to run
- F2: the flame went out while the boiler was running
The rest of the Keston codes are in one list on the Keston page.
Biasi: Er, E or A and two figures, or lights
Biasi's Advance Plus shows Er and two figures. The Antares, RinNova and Dina number their codes their own way, and the Riva uses three lights. The same number can mean different things on each range. Which Biasi boiler shows which kind of code.
- Er 01: the burner didn't light (Advance Plus)
- Er 02: the overheat thermostat has tripped (Advance Plus)
- Er 04: no water, or no flow (Advance Plus)
- Er 05: a fault in the fan's control (Advance Plus)
- Er 14: the pump, or water above 105°C (Advance Plus)
- Er 25: a flame detection error (Advance Plus)
The rest of the Biasi codes are in one list on the Biasi page.
ATAG: three characters, such as 501 or 1P4
ATAG boilers from 2019 show three characters, such as 501 or 1P4, with a spanner or a bell. Boilers from 2015 to 2018 show two or three figures, and a few of those mean something else. Which ATAG boiler shows which kind of code.
- 108 and 1P4: the pressure is too low
- 501: no flame detected
- 101: an overheat
- 103 to 107: the flow checks have failed
- 109: the pressure is too high
- 304: too many resets
- 118 and 133: low pressure or a sensor fault on 118, by the boiler's age, and no flame on 133
The rest of the ATAG codes are in one list on the ATAG page.
Intergas: F and three figures, or a number and a red light
Intergas's Xclusive and Xtreme show F and three figures on a touch screen, such as F004. The HRE, ECO RF and Rapid show a number on the main display, with a red light flashing above the reset key. The small service display's numbers are what the boiler is doing, not faults. Which Intergas boiler shows which kind of code.
- F004: no flame when lighting
- F005: the flame was lost while running
- F001: too hot while heating
- F003: the flue gases are too hot
- F008: the fan speed is wrong
- F018: the flue or air supply is blocked
- F010 and F011: the heat exchanger sensor
The rest of the Intergas codes are in one list on the Intergas page.
Main: a number, an E code or a light
Main Eco Compact boilers, now sold as the Baxi MainEco Compact, flash a number, such as 133, with an R when you may reset it. The older Eco Elite shows the same faults with an E, such as E133, and the Eco Compact Heat a light. Low pressure is 118 on one and E119 on the other. Which Main boiler shows which kind of code.
- 133 or E133: the gas supply, the spark or the flame failed
- 118 (Eco Compact) or E119 (Eco Elite): the water pressure is too low
- 110 or E110: the boiler has overheated
- 125 or E125: the water isn't moving round well enough
- 128: the flame went out while the boiler was running
- 160 or E160: the fan or its wiring
The rest of the Main codes are in one list on the Main page.
Ferroli: A or F and two figures
Ferroli's Bluehelix boilers show A codes and F codes, such as A01 or F37. An A code locks the boiler out until it is reset, and an F code clears when the cause does. The Modena and T-One use the same letters, and some numbers mean something else on each range. Which Ferroli boiler shows which kind of code.
- A01: the burner didn't light
- F1 (01) on an Optimax 25 S: the burner didn't light
- A06: the flame went out after lighting
- F37 and F40: the water pressure is too low, or too high
- A08, A09 and A03: the boiler overheated
- F05 and A05 (F15 on a Modena): the fan isn't running at the right speed
- F10: the flow temperature sensor has failed
- A14 and A07 (A04 on a Modena): the flue gases ran too hot
The rest of the Ferroli codes are in one list on the Ferroli page.
Ravenheat: two figures and an E, a number, or a light
Ravenheat's CS80, CS90 and HE boilers show two figures and an E, such as 01E. The CSI 120, CSI 150 and HE 42 show a number alone, such as 01 or 28, which doesn't match the E codes. Older boilers show a red light. Which Ravenheat boiler shows which kind of code.
- 01E (01 on the boilers that show a number alone): the boiler couldn't light, and has locked out
- 08E (28 on the boilers that show a number alone): the water pressure is too low
- 12E: too many resets
- 06E, 09E, 21E and 29E (04 on the boilers that show a number alone): the boiler has overheated. 02E means the water isn't moving
- 22E and 23E (30 and 31 on a WH 100 or WH 130): the flue is too hot, or its sensor has failed
- 25E: the main heat exchanger has frozen
The rest of the Ravenheat codes are in one list on the Ravenheat page.
Heatline: F and one or two figures, or lights
Heatline's Capriz 2 shows F. and two figures, such as F.28, and the CaprizPlus and Monza the same without the dot. The Solaris, Sargon and Vizo Plus show F and one figure, and older boilers show flashing lights. The same number can mean something else on an older one. Which Heatline boiler shows which kind of code.
- F28 (F.28): the boiler tried to light and failed
- F29: the flame went out while running
- F22 (F.22): the water pressure is too low
- F20: the boiler has overheated
- F32: the fan or the air pressure
- F00, F01, F10 and F11: a temperature sensor
The rest of the Heatline codes are in one list on the Heatline page.
Sime: ALL or AL and two figures
Sime's Edea shows ALL and two figures, such as ALL 02, and the Giulia AL with the same numbers. On the Edea T system boiler two of them swap, and older Murelle boilers have a list of their own. Which Sime boiler shows which kind of code.
- ALL 02 (AL 02): the water pressure is too low
- ALL 06 (AL 06) and ALL 41: no flame, or the flame keeps going out
- ALL 07 (AL 07): the overheat thermostat has tripped
- ALL 09 (AL 09): no water moving round the heating
- ALL 15 (AL 15): a fan fault
- ALL 18: condensate is backing up (Edea)
- ALL 28 (AL 28): too many resets in a row
The rest of the Sime codes are in one list on the Sime page.
Remeha: e and a number, or a letter and four figures
Remeha's Avanta boilers show e and a number, taking turns on the display, so e then 2 is e2. The Avanta Plus added e9 for low pressure. Newer Remeha boilers, such as the Quinta Ace, show codes like E.04.10. Which Remeha boiler shows which kind of code.
- e4: the burner didn't light
- e5: the flame went out
- e9: the water pressure is too low
- e1: the boiler has overheated
- e7 and e10: no water, or no flow
- e8: a fan fault
- e0: a temperature sensor fault
The rest of the Remeha codes are in one list on the Remeha page.
Megaflo: E and three figures, on the system boilers
Megaflo is two products. Megaflo unvented cylinders show no code. Baxi's Megaflo system boilers show E and three figures, such as E118 for low water pressure, where many Baxi boilers show E119. Which Megaflo boiler shows which kind of code.
- E118 (not E119): the water pressure is too low
- E133: the gas supply was interrupted, or the flame didn't light or wasn't detected
- E110: the safety thermostat has tripped, from overheating
- E125: the heating water isn't circulating
- E117: the water pressure is too high
- E128: the flame went out while the boiler was running
- E160: the fan or its wiring
The rest of the Megaflo codes are in one list on the Megaflo page.
Powermax: a letter and a number, or lights
The Potterton Powermax HE's red display shows A for a lockout, E for an error and P for the heating pressure, such as A 01. The older Range Powermax shows its faults with lights. Which Powermax boiler shows which kind of code.
- A 01: the burner did not light (Powermax HE)
- A 15 or P 0.1 to 0.4: the heating pressure is lost (Powermax HE)
- P 3.0 to 3.5, or E 01: the heating pressure is too high (Powermax HE)
- A 03 and E 03: an overheat lock-out, the flow too hot (Powermax HE)
- A 40 (A 02 in the user's instructions): a system response fault (Powermax HE)
- E 20 and A 20: a flame sensed with the gas valve closed (Powermax HE)
- Red light: the Range Powermax's red lock-out light
The rest of the Powermax codes are in one list on the Powermax page.
Geminox: three figures, shown in two parts
Geminox boilers show a code of three figures, such as 133. The THI's two-digit display shows it in two parts, a 1 and then 33. The same number can mean something else on the THRs. Which Geminox boiler shows which kind of code.
- 118 (323 on a THRs): the water pressure is too low
- 117: the water pressure is too high
- 133: no flame, so the boiler has locked out (E 1, then 33, on a ZEM)
- 153: the boiler is locked
- 110: the overheat safety has tripped (on a THRs, the underfloor limiter)
- 128: the flame went out while the boiler was running
- 160: the fan isn't reaching its minimum speed
The rest of the Geminox codes are in one list on the Geminox page.
How to find your boiler's make and model
A boiler's make and model are on its casing, where you can read them without opening it. The maker's name is on the front. The model, often with the serial number, is on a data plate or label. Here is where the makers say to look:
- Vaillant and Glow-worm: the data plate, under the boiler.
- Worcester Bosch: the front of the boiler, or the data label inside its door.
- Baxi: a pull-out tab under the front of the boiler, for the serial number.
- Potterton: the information label at the front.
- Biasi and ATAG: a sticker or the flap at the front.
Never take the case off to look. If you can't find the model, ring us anyway. We'll ask what the display shows, and the code and the way it shows often name the range.
What a fault code can and can't tell you
A fault code tells you what the boiler's sensors found, not which part has failed. F28, for one, means the boiler couldn't light. Vaillant's manual lists five groups of causes behind it, from the gas supply to the control board. The code shows an engineer where to start, and finding the cause is the work.
The same code can mean different things on different boilers. F1 is low water pressure on an Ideal, and an ignition fault on an older Glow-worm. Low pressure is E119 on a Potterton Promax, and E118 on a Potterton Assure. Read the make and model before the code, and we'll ask for both when you ring.
A lockout is the boiler keeping you safe. When it finds a fault it shouldn't run with, the boiler stops and waits for a reset. Some codes clear by themselves once the cause has gone. On the current Vaillant ecoTEC plus, low pressure clears once the system is topped up.
Worth knowing
On a Baxi Main Eco or a Potterton Assure, an R beside the code means you may reset it at home. A spanner means it needs an engineer.
Do you cover my part of London?
Yes, we fix boiler faults all over Greater London, in every borough north and south of the Thames. Pick your side of the river to see the areas.
North of the river
Every borough north of the Thames: Barnet and Enfield at the top, Hillingdon in the west, Havering in the east, and central London in between.
South of the river
Every borough south of the Thames: Richmond and Kingston in the west, Bexley in the east, and down through Croydon to Sutton and Bromley.
Questions about boiler fault codes
Can I clear a fault code myself?
A fault code can be cleared at home when the maker's user guide says so. It might be a reset, or topping up the pressure where the guide shows how. The guides set a limit on resets. Most Vaillant and Glow-worm boilers allow three, and an Ideal locks out with LC after five restarts in 15 minutes. If the code comes back, the fault needs an engineer.
Is it safe to reset the boiler?
A reset is safe to try when the user guide allows it and you can't smell gas. If you smell gas, don't reset anything. Open the gold "Smell gas?" bar on this page for the free emergency number. Never open the boiler's case to reach a reset or a part.
Why does the code keep coming back?
A code that keeps coming back means its cause is still there. The reset clears the display, not the fault. Some causes come and go, such as a gas supply that drops or a condensate pipe that refreezes overnight. That's why a code can clear and return. An engineer tests each cause in turn.
Which codes mean the boiler must stay off?
Any code that comes back after the resets the guide allows means the boiler should stay off until an engineer has looked at it. The same goes for any fault with a smell of gas. Some makers mark the codes that need an engineer. There's a spanner on a Baxi Main Eco or a Potterton Assure, and an engineer symbol on a Biasi Advance Plus. Vaillant's manuals say a fault such as F.27 shouldn't be reset at all.
How much does it cost to fix a fault code?
The cost of fixing a fault depends on its cause and the part it needs, if any. The rate is agreed on the call, before an engineer comes, and no work is done until you say yes. How our rates work.
Don't know what has failed? You don't have to.Ring and say what you can see or hear. Finding the fault is our job.
Calls answered 24 hours a day
A real person answers and gives you the rate on the call. No work starts until you say yes, and repairs are guaranteed for 12 months: parts, labour and any return visit.